Dialing with vm
Uwe Bonnes (bon@elektron.ikp.physik.th-darmstadt.de)
Wed, 22 Jan 1997 14:43:00 +0100
Hallo,
I have an ELSA MicroLink modem, connected to ttyS3. It is connected to an
analog line on an internal (siemens) telephone sysstem, with no right to
dial outside the internal net. The lines don't have the standard dialtone,
so I do have
port ttyS3
init-chat "" ATS0=0Q0&D3&C1X3L0P OK
in mgetty.config. I can play and record
messages, send and receive faxes and to data communication. However, I can't
successfully dial with "vm" .Doing
bash# vm dial -l ttyS3 -x 6 -t -v 2516
vm: dialing number 2516
I hear the modem pick up the line, wait some seceonds, then pulse-dial the
"2" and "5", but then vm switches off. Here the (I think) interesting part of
vm.log. Can anybody enlighten me, what's going wrong? Thanks
01/22 14:24:15 tio_set_flow_control( HARD )
01/22 14:24:15 detecting voice modem type
01/22 14:24:15 vm: ATE1
01/22 14:24:15 voice command: '' -> 'OK|ATE1'
01/22 14:24:15 serial port: ATE1
01/22 14:24:15 serial port: OK
01/22 14:24:15 modem detected
01/22 14:24:15 voice command: 'ATI' -> ''
01/22 14:24:15 vm: ATI
01/22 14:24:15 serial port: ATI
01/22 14:24:15 serial port: 282
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 Elsa MicroLink detected
01/22 14:24:15 initializing Elsa voice modem
01/22 14:24:15 vm: entering voice mode
01/22 14:24:15 vm: Installing signal handlers
01/22 14:24:15 voice command: 'AT#CLS?' -> ''
01/22 14:24:15 vm: AT#CLS?
01/22 14:24:15 Elsa MicroLink: AT#CLS?
01/22 14:24:15 Elsa MicroLink: 2
01/22 14:24:15 voice command: '' -> 'OK'
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT#CLS=8' -> 'OK'
01/22 14:24:15 vm: AT#CLS=8
01/22 14:24:15 Elsa MicroLink: AT#CLS=8
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT' -> 'OK'
01/22 14:24:15 vm: AT
01/22 14:24:15 Elsa MicroLink: AT
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT#VSP=40' -> 'OK'
01/22 14:24:15 vm: AT#VSP=40
01/22 14:24:15 Elsa MicroLink: AT#VSP=40
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT#VSD=0' -> 'OK'
01/22 14:24:15 vm: AT#VSD=0
01/22 14:24:15 Elsa MicroLink: AT#VSD=0
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT#VBS=4' -> 'OK'
01/22 14:24:15 vm: AT#VBS=4
01/22 14:24:15 Elsa MicroLink: AT#VBS=4
01/22 14:24:15 Elsa MicroLink: OK
01/22 14:24:15 voice command: 'AT#BDR=16' -> 'OK'
01/22 14:24:16 vm: AT#BDR=16
01/22 14:24:16 Elsa MicroLink: AT#BDR=16
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT#VTD=3F,3F,3F' -> 'OK'
01/22 14:24:16 vm: AT#VTD=3F,3F,3F
01/22 14:24:16 Elsa MicroLink: AT#VTD=3F,3F,3F
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT#VSS=1' -> 'OK'
01/22 14:24:16 vm: AT#VSS=1
01/22 14:24:16 Elsa MicroLink: AT#VSS=1
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'ATS30=60' -> 'OK'
01/22 14:24:16 vm: ATS30=60
01/22 14:24:16 Elsa MicroLink: ATS30=60
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT\Q3' -> 'OK'
01/22 14:24:16 vm: AT\Q3
01/22 14:24:16 Elsa MicroLink: AT\Q3
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 tio_set_flow_control( HARD )
01/22 14:24:16 vm: leaving voice mode
01/22 14:24:16 voice command: 'AT#CLS=2' -> 'OK'
01/22 14:24:16 vm: AT#CLS=2
01/22 14:24:16 Elsa MicroLink: AT#CLS=2
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT' -> 'OK'
01/22 14:24:16 vm: AT
01/22 14:24:16 Elsa MicroLink: AT
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 vm: Restoring signal handlers
01/22 14:24:16 vm: entering voice mode
01/22 14:24:16 vm: Installing signal handlers
01/22 14:24:16 voice command: 'AT#CLS?' -> ''
01/22 14:24:16 vm: AT#CLS?
01/22 14:24:16 Elsa MicroLink: AT#CLS?
01/22 14:24:16 Elsa MicroLink: 2
01/22 14:24:16 voice command: '' -> 'OK'
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT#CLS=8' -> 'OK'
01/22 14:24:16 vm: AT#CLS=8
01/22 14:24:16 Elsa MicroLink: AT#CLS=8
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'AT' -> 'OK'
01/22 14:24:16 vm: AT
01/22 14:24:16 Elsa MicroLink: AT
01/22 14:24:16 Elsa MicroLink: OK
01/22 14:24:16 voice command: 'ATD2516' -> ''
01/22 14:24:16 vm: ATD2516
01/22 14:24:16 Elsa MicroLink: ATD2516
01/22 14:24:22 vm: timeout while reading character from voice modem: No \
such file or directory
01/22 14:24:22 Elsa MicroLink: _NO_DEV: (1)
01/22 14:24:22 voice command: 'AT#VLS=0' -> 'OK'
01/22 14:24:22 vm: AT#VLS=0
01/22 14:24:22 Elsa MicroLink: OK
01/22 14:24:23 Elsa MicroLink:
01/22 14:24:29 vm: timeout while reading character from voice modem: Transport
endpoint is not connected
01/22 14:24:29 vm: leaving voice mode
01/22 14:24:29 voice command: 'AT#CLS=2' -> 'OK'
01/22 14:24:29 vm: AT#CLS=2
01/22 14:24:29 Elsa MicroLink: AT#CLS=2
01/22 14:24:29 Elsa MicroLink: OK
01/22 14:24:29 voice command: 'AT' -> 'OK'
01/22 14:24:29 vm: AT
01/22 14:24:29 Elsa MicroLink: AT
01/22 14:24:29 Elsa MicroLink: OK
01/22 14:24:29 vm: Restoring signal handlers
01/22 14:24:29 closing voice modem device
01/22 14:24:29 removing lock file
--
Uwe Bonnes bon@elektron.ikp.physik.th-darmstadt.de
Institut fuer Kernphysik Schlossgartenstrasse 9 64289 Darmstadt
--------- Tel. 06151 162516 -------- Fax. 06151 164321 ----------