Timeout for AutoPPP login - and an add-on for the mgetty/vgetty program...
Gert Doering (gert@greenie.muc.de)
Tue, 6 Jul 1999 21:40:33 +0200
Hi,
On Tue, Jul 06, 1999 at 10:32:17AM +0200, Marc SCHAEFER wrote:
> On Tue, 6 Jul 1999, Gert Doering wrote:
>
> > - return <0> - answer immediately
> > - return <1> - do not answer at all, never
>
> I would split between REJECT and IGNORE call. With current technology
> (ZyXEL) you do ATH0 in both cases, and if no other device is there,
> it BUSies.
ok, so let's do this:
0 - answer immediately (same as "10", actually)
1 - ignore call
2 - reject call (ignore call if no REJECT possible)
3 - "ask me again"
10 + <n> - answer in <n> RINGs from now
> > - return <2> - "ask me again" -> cnd-program will be called again after
> > next RING, and can then return 0/1/2 again
>
> This is exactly the interface of my CND program patch. Only difference
> is that ask me again is not implement in mgetty yet (or maybe it is,
> now).
Well, yes, basically the new concept came from your patch.
gert
--
USENET is *not* the non-clickable part of WWW!
//www.muc.de/~gert/
Gert Doering - Munich, Germany gert@greenie.muc.de
fax: +49-89-35655025 gert.doering@physik.tu-muenchen.de