vgetty mit Elsa MicroLink 28.8 TQV

Gert Doering (gert@greenie.muc.de)
Tue, 21 Sep 1999 09:12:47 +0200


Hi,

On Mon, Sep 20, 1999 at 06:11:39PM +0200, Sebastian Kaps wrote:
> Ich verwende vgetty aus dem m+s-1.1.21 Paket. Wenn ein Anruf ankommt
> erscheint nach dem ersten oder zweiten Klingeln folgendes im
> vgetty-Logfile:
> 
> ---------->> cut here ----------
> 09/16 17:03:07 yS1  detecting voice modem type
> 09/16 17:03:09 yS1  Elsa MicroLink detected
> 09/16 17:03:09 yS1  initializing Elsa voice modem
> 09/16 17:03:11 yS1  waiting...
> 09/16 17:03:15 yS1  wfr: waiting for ``RING''
> 09/16 17:03:25 yS1  mdm_read_byte: read returned -1: Interrupted system call
> 09/16 17:03:25 yS1  wfr: timeout waiting for RING
> 09/16 17:03:25 yS1  huh? Junk on the line?

Could be a mismatch between the "speed" settings in mgetty.config and
voice.conf - make sure both files have the *same* "speed <nnn>" setting.

Yes, this is a bug (kind of).

If that doesn't help, please post a log file with "vgetty -x6", so that
we can actually see what's going on.

gert
-- 
Gert Doering
Mobile communications ... right now writing from *Amsterdam* :-)) 
... mobile phone: +49 177 2160221 ... or mail me:  gert@greenie.muc.de