Elsa 56k - Firmware later than 1.29
Frank Doepper (woffs@doepper.leipzig.netsurf.de)
Thu, 5 Nov 1998 18:21:57 +0100
Hi,
answering a incoming data call with vgetty (yes, latest version too)
succeeds using a Highscreen BahnBoostar=Elsa Microlink 56k Modem with
Firmware 1.29:
10/27 00:13:09 yS1 Elsa MicroLink: <VOICE DATA 24895 bytes>
10/27 00:13:09 yS1 Elsa MicroLink: <DLE> <ETX>
10/27 00:13:09 yS1 voice command: '' -> 'OK|VCON'
10/27 00:13:09 yS1 Elsa MicroLink: VCON
10/27 00:13:09 yS1 vgetty: trying data and fax connection
10/27 00:13:09 yS1 voice command: 'AT#CLS=2' -> 'OK'
10/27 00:13:09 yS1 vgetty: AT#CLS=2
10/27 00:13:09 yS1 Elsa MicroLink: OK
10/27 00:13:09 yS1 voice command: 'AT+FAA=1' -> 'OK'
10/27 00:13:09 yS1 vgetty: AT+FAA=1
10/27 00:13:09 yS1 Elsa MicroLink: OK
and fails using Firmware 1.52 or 1.46:
10/26 19:00:34 yS1 Elsa MicroLink: <VOICE DATA 22823 bytes>
10/26 19:00:34 yS1 Elsa MicroLink: <DLE> <ETX>
10/26 19:00:34 yS1 voice command: '' -> 'OK|VCON'
10/26 19:00:34 yS1 Elsa MicroLink: VCON
10/26 19:00:34 yS1 vgetty: trying data and fax connection
10/26 19:00:34 yS1 voice command: 'AT#CLS=2' -> 'OK'
10/26 19:00:34 yS1 vgetty: AT#CLS=2
10/26 19:00:34 yS1 Elsa MicroLink:
[e0][e0][00][00][e0][00][e0][00][e0][e0][e0][00][e0][e0][e0][00][00][e0][00]
10/26 19:00:45 yS1 vgetty: timeout while reading character from voice modem
10/26 19:00:45 yS1 vgetty: Could not switch to data/fax mode
Is this known? What's going wrong? Why this? Anyone else?
F.
--
http://www.imn.htwk-leipzig.de/~fdoeppe/
PGP: 1024/9B6F43AD 1997/06/01 3A 8A 31 F2 48 C9 1F CA CF 60 3A C5 8D 1C 5F CF